Navi Mumbai
+917045379291

'demand precision'

Items tagged with 'demand precision'

product image
NITROGEN EVAPORATOR

Adapting to evolving laboratory demands and projects requiring ultra-low sample volumes, the SpeedoVap 96WP (96 Well-plate) Nitrogen Evaporator is a cutting-edge solution. As an alternative to water-bath evaporators, this well-plate evaporator utilizes heated dry air for efficient solvent evaporation. Key Features: • Unattended operation for streamlined processing. • Configurable for well-plates of 1000μL and 2000μL capacities. • Controlled heated block adjustable from ambient to 70 °C. • Built-in nitrogen regulator for efficient operation. • LED display for enhanced visibility under a fume hood. • Compact size requiring no hood space. • Exhaust options open to the atmosphere or within a Fume Hood. • Alarms for various processes to draw user attention. • Small footprint for space-efficient lab setups. Operational Design: This closed hood well-plate evaporator employs a micro-processor to control and maintain the dry-block well-plate bay. Nozzles direct dry air into the wells for drying, with temperature and time settings for precise operation. Nitrogen gas, blown through nozzle manifolds into samples, automatically turns off after the process is completed. Audio alarms indicate completion. Applications: Ideal for diagnostic labs and research involving low volumes, the SpeedoVap 96 Well-plate evaporator is a valuable addition to testing labs seeking efficient and controlled sample processing. Conclusion: Experience the efficiency of ultra-low sample volume processing with the SpeedoVap 96WP Well Plate Nitrogen Evaporator. With its advanced features and unattended operation, this versatile solution is tailored for laboratories with dynamic demands, ensuring precision in solvent evaporation. Technical Specifications :- Maximum Number of Samples : 96 Well-plate Bay Supplied : One Well-plate Dry Block Temperature : Ambient to 70 °C. Timer Range : 1 min to 9.50 hours/indefinite Gas Supply Requirements : Inlet pressure 100 psi Gas control : Gas can be turned ‘ON’ for any / each of s Gas Regulator and Gas Gauge Range : Provided – manually adjustable. Gas Flow required : 170 LPM Exhaust : In-built , Duct hose provided Power Requirements : 230 VAC at 50 Hz Dimensions (WxDxH): 17.25” X 13.5” X 11” (44 X 34 X 28 cms) Net Weight : 9.5 kg Shipping Weight : 15 kg Technology : Sample Vortexing Certifications : 2004/22/EC Measuring Instruments Directive, 2014/35/EU Low Voltage Directive 2009/105/EC Simple Pressure Vessels.

Send Message
product image
NITROGEN EVAPORATOR

For laboratories with specific requirements for solvent retention and reconstitution, the SpeedoVap Optical Endpoint Nitrogen Evaporator offers a tailored solution. Unlike standard High Volume Nitrogen Evaporators, this specialized instrument is designed for applications demanding precise endpoint volumes of 0.5 mL, 1 mL, or 2 mL. Key Features: • Unattended operation for endpoint evaporation as desired by user, eliminating the need for constant monitoring. • Controlled water bath adjustable from ambient to 80 °C. • Built-in nitrogen regulator for enhanced control. • LED display for better visibility under a fume hood. • Compact size, requiring minimal hood space. • Exhaust open to the atmosphere or within a fume hood. • Easy-to-use water drain pump with a small footprint. Unique Features: • Set program cannot be changed once the process has begun. • User-requested endpoint volume options at 0.5 mL, 1.0 mL, or 2.0 mL. • Individual process stops at each station as the endpoint is attained, ensuring precision. Endpoint Test Tubes: Specially designed endpoint test tubes, available in volumes of 100 mL or 200 mL and calibrated for 0.5 mL, 1 mL, 2 mL, and 100 mL or 200 mL for seamless reconstitution. Applications: Ideal for laboratories where a specific volume of solvent must be retained at the end of evaporation before analysis, the SpeedoVap Optical Endpoint Nitrogen Evaporator offers unparalleled control and precision. Conclusion: Experience unmatched accuracy and convenience in evaporation with the SpeedoVap Optical Endpoint Automatic Nitrogen Evaporator. Designed for precise endpoint volume control, this instrument streamlines processes for laboratories with specific solvent retention requirements. ___________________________________________________________________________________________________________________________________________________________ Technical Specifications :- Maximum Number of Samples : 6 Max. sample volume : 100 mL / 200 mL End Point Setting : As per test tube at 0.5 mL,1.0 ml or 2.0 mL Rack Supplied: One Rack with one pre-set endpoint supplied with system. For alternate requirement, connect with us. Water Bath Temperature : Ambient to 80 °C. Timer Range : 1 min to 9.50 hours/indefinite Gas Supply Requirements : Min. inlet pressure 70 psi Max. inlet pressure 100 psi Gas Regulator and Gas Gauge Range : Provided – manually adjustable. Station Control : Each station can be individually controlled at the programme start End point technology : Micro processor based, Optical sensors Gas Flow Required : 30 LPM Exhaust : In-built , Duct hose provided Power Requirements : 230 VAC at 50 Hz (110 VAC –available on request) Dimensions (WxDxH) : 25" x 14"x 13.25" (63.5 x 35.6 x 33.7 cm) Net Weight : 18 kg Shipping Weight : 25 kg Technology : Vortex Technology Certifications : 2014/35/EU Low Voltage Directive 2014/35/EU Low Voltage Directive 2009/105/EC Simple Pressure Vessels. ISO9001:2015 Gas control : Gas can be turned ‘ON’ for any/each of six independent stations Test Tubes (Dimensions as per catalogue or availability) Capacity in mL Dimensions in mm (OD X H) 100 mL 0.5 mL, 1 mL, 2.0 mL 200 mL 0.5 mL, 1 mL, 2.0 mL We also supply the End Point test tubes with calibration certificate.

Send Message
product image
NITROGEN EVAPORATOR

SpeedoVap HV, a High-Volume Nitrogen Evaporator & Concentrator, is engineered to handle large sample volumes, making it a crucial tool in Environmental and Soil Testing laboratories. With the capacity to evaporate 8-15 samples in a batch, this instrument offers flexibility and efficiency for applications requiring volumes of 50 mL to 300 mL. Key Features: • Interchangeable racks for accommodating various large volume test tubes or beakers. • Micro-processor control ensures precise temperature maintenance during operation. • Gas control with selectable manifolds for customizable nitrogen flow based on sample quantity. • Rust-resistant stainless steel nozzle manifolds with automatic shutdown after completion, signaled by audio alarms. Applications: Primarily used in Environmental and Soil Testing laboratories, SpeedoVap HV extends its utility to water testing and the food processing industry. Its versatility and reliability make it an indispensable tool for applications demanding precise sample concentration. Specialized Model: Takahe introduces a unique solution – the SpeedoVap HV Optical Endpoint Nitrogen Evaporator, designed for applications requiring evaporation to a set volume. Features: • Unattended operation for up to 15 samples (Glassware determines the number of samples). • Different interchangeable racks available for various tube sizes. • Controlled water bath adjustable from ambient to 80 °C. • Built-in nitrogen regulator for enhanced control. • LED display for better visibility under a fume hood. • Convenient size requiring no hood space. • Exhaust open to the atmosphere or within a fume hood. • Easy-to-use water drain pump. Unique Features: • Set program cannot be changed once the process has begun. • Printing and data storage facility available. • Option for a Combo Evaporator catering to both Low Volume and High Volume applications, minimizing costs and maximizing efficiency. ___________________________________________________________________________________________________________________________________________________________ Technical Specifications :- Maximum Number of Samples : 15 Max. sample volume : 300 mL Rack Supplied : Any one Rack listed based on requirement. (additional racks can be ordered separately) Water Bath Temperature : Ambient to 80 °C. Timer Range : 1 min to 9.50 hours/indefinite Gas Supply Requirements : Min. inlet pressure 70 psi Max. inlet pressure 100 psi Individually controlled -Gas can be turned ‘ON’ for any/ each of three independent manifolds Gas Regulator and Gas Gauge Range : Provided – manually adjustable. Gas Flow Required : 50 LPM Exhaust : In-built, Duct hose provided Power Requirements : 230 VAC at 50 Hz (110 VAC –available on request) Dimensions (WxDxH) : 25" x 14"x 13.25" (63.5 x 35.6 x 33.7 cm) Net Weight : 18 kg Shipping Weight : 25 kg Technology : Vortex technology Certifications : 2004/22/EC Measuring Instruments Directive, 2014/35/EU Low Voltage Directive 2009/105/EC Simple Pressure Vessels. Gas Control : Gas can be turned ‘ON’ for any/ each of three independent manifolds Test Tubes (Dimensions as per catalogue or availability) Capacity in mL Dimensions in mm (OD X H) 75 29 X 116 (Conical centrifuge tubes) 100 29 X 135 (Conical centrifuge tubes) 100 25 X 150 125 25 X 200 175 32 X 200 200 38 X 200 Bottles Reagent, Wide Mouth With Screw Cap And Pouring Ring (Borosil) Capacity in mL Dimensions in mm (OD X H) 25 36 X 70 50 46 X 87 100 56 X 100 250 70 X 138 Beakers, Low Form (Borosil) Capacity in mL Dimensions in mm (OD X H) 25 35 X 45 50 40 X 58 100 50 X 75 150 55 X 88 250 70 X 95 500 85 X 115

Send Message
product image
NITROGEN EVAPORATOR

For laboratories that prioritize sample integrity and seek a contamination-free evaporation process, the SpeedoVap Dry Block Nitrogen Evaporator stands out as the ideal solution. Utilizing dry heat, this model offers a reliable and efficient approach to sample evaporation with minimal chances of contamination. Key Features: • Utilizes dry heat for contamination-free sample evaporation. • Preferred choice for laboratories prioritizing sample integrity. • Efficient and reliable evaporation process. Benefits of Dry Block Evaporation: The SpeedoVap Dry Block Nitrogen Evaporator is chosen by laboratories that prefer the use of dry heat for sample evaporation. This method reduces the risk of contamination, ensuring the integrity of samples throughout the evaporation process. The efficient design of this model guarantees reliable results while maintaining the highest standards of sample purity. Applications: Ideal for laboratories across various industries that prioritize contamination-free sample evaporation, the SpeedoVap Dry Block Nitrogen Evaporator offers a reliable solution. Whether in pharmaceuticals, research, or other fields, this model ensures the preservation of sample integrity. Conclusion: Choose the SpeedoVap Dry Block Nitrogen Evaporator for a contamination-free and efficient sample evaporation process. With its reliance on dry heat, this model is the preferred choice for laboratories that prioritize sample integrity and demand reliable results in their evaporation processes. ___________________________________________________________________________________________________________________________________________________________ Technical Specifications : - Maximum Number of Samples : 15 Max. Sample Volume : 15 mL Rack Supplied : One block for any one test tube size (options – Eppendorf, Ria vial, Tarson Centrifuge tube) Heat Block : Ambient to 80°C. Timer Range : 1 min to 9.50 hours/indefinite Gas Supply Requirements : Min. inlet pressure 70 psi Max. inlet pressure 100 psi Gas can be turned ‘ON’ for any/ each of three independent manifolds Gas Regulator and Gas Gauge Range : Provided – manually adjustable. Gas Flow required : 45 LPM Exhaust : In-built , 1 m Duct hose provided Power Requirements : 230 VAC at 50 Hz Net Weight : 18 kg Shipping Weight : 25 kg Certifications : 2004/22/EC Measuring Instruments Directive, 2014/35/EU Low Voltage Directive 2009/105/EC Simple Pressure Vessels.

Send Message
product image
NITROGEN GENERATOR

A Nitrogen generator produces nitrogen gas from compressed air. Nitrogen is a colorless gas that makes up 78% of the Earth's atmosphere. It is non-flammable and non-reactive, making it an ideal gas for many industrial and commercial applications. Productive time of analysts and users spent in follow-up for cylinder procurement, change and daily installation of cylinders are eliminated. In operations, cylinders having high cylinder pressure creates a safety issue which is also now addressed with the Nitrogen Generator. With high requirement of Nitrogen for the Nitrogen evaporator and Nitrogen Solvent concentrator, the Nitrogen Generator is a simple solution for tedious logistics, high cost of cylinders and vendor dependency. PSA Nitrogen Generator PSA nitrogen generators use a pressure swing adsorption (PSA) process to separate nitrogen from oxygen in the air. PSA Nitrogen Generator uses two towers filled with carbon molecular sieve (CMS). The "online" tower is filled with compressed air that flows through the CMS. Nitrogen passes through the CMS while oxygen and other trace gases are absorbed. Once a pre-set time has passed, the on-line tower automatically switches to regenerative mode, venting contaminants. In contrast to ordinary activated carbon, carbon molecular sieve has a much smaller range of pore openings. Nitrogen molecules are too large to enter the CMS, so oxygen penetrates the pores and we get pure Nitrogen. Our nitrogen generators are delivered as complete systems, complete with air filters and automatic controls to hook up to a compressed air supply. Start up your PSA Nitrogen Generator by switching it on, and you're ready to start. Also, maintenance is easy. PSA Nitrogen Generator filters only need to be changed once every six to twelve months, depending on your usage. Intelligent Control Our in-house developed software process controller generates the output of Nitrogen by optimising the functions to increase compressor life and reduce running costs over long periods of use. Switching to Nitrogen Generator is a wise decision Recover your operating expense by investing in your capital. Clean particulate free nitrogen with certified purity. Nitrogen supplied on demand. No dependency on vendors and maintenance man-power. Eliminate periodic logistics of cylinder procurement. Features of Nitrogen Generator Silent and seamless Nitrogen gas supply to your lab. Compact non-obstructive design with the option of wall-mounting and free up precious space. In-built service features to indicate timely routine maintenance. Automatically switches to standby mode when Nitrogen is not required - thereby reducing wear & tear of the compressor. Advantages of Nitrogen Generator? Reduced costs: Nitrogen generators can be a more cost-effective option than buying nitrogen gas from a supplier. Increased safety: On-site nitrogen generation can help to improve safety by reducing the need for nitrogen gas cylinders, which can be a safety hazard if handled by untrained personnel Increased convenience: Nitrogen generators can provide a convenient and reliable source of nitrogen gas, which can be used on demand. FAQ- What makes us different from other Nitrogen Generator companies? There are several factors that make us different from other Nitrogen Generator. One factor is our experience. We have been designing, manufacturing, and selling Nitrogen Generator for over 4 years. With discussions with our users we have a deep understanding of their needs helping us to provide them with high-quality products and services. Our Nitrogen Generator has a dedicated design team and manufacturing team. We have a strict quality control system and professional testing equipment and we have a strong R&D team. Another factor that makes us different is our commitment to customer service. We have a team of highly trained and experienced customer service representatives who are available to answer any questions that our customers may have. We also offer a 100% satisfaction guarantee on all of our products and services.

Send Message

Still searching for
demand precision?